A.to increase the system efficiency by sensible heat transfer
B.to stop the liquid from flashing
C.to reduce the load on the compressor
D.to remove latent heat of vaporization and the suction piping transfer
您可能感兴趣的试卷
你可能感兴趣的试题
A.its pressure and temperature are both lowered
B.its pressure and temperature are both raised
C.its pressure is lowered and its temperature is raised
D.its pressure is raised and its temperature is lowered
A.thermal valve
B.magnetic stop valve
C.bellows valve
D.bimetallic valve
A.high-pressure cutout switch is jammed open
B.low-pressure switch is jammed shut
C.thermal bulb is not operating properly
D.scale trap is clogged
A.in the middle of evaporator coils
B.near the evaporator coil outlet
C.near the evaporator coil inlet
D.on the bottom row of evaporator coils
A.amount of superheat in the vapor leaving the coil
B.amount of superheat in the liquid
C.temperature in the evaporator coils
D.pressure in the evaporator coils
A.stop the refrigerant from flowing
B.force the refrigerant to flow
C.cause the refrigerant pressure to rise
D.cause the refrigerant pressure to fall
A.the expansion valve will move toward the wide open position
B.the expansion valve will move toward the closing position
C.the feeler bulb will conveys the high temperature
D.the superheat degree will raise
A.move in an opening direction
B.move in a closing direction
C.either open or close
D.not move at all
A.help preheat the air for the furnaces
B.help preheat the feedwater
C.protect economizer from excessive heat
D.prevent excessive furnace heat losses
A.the bilges
B.the periscope
C.the water level
D.the oil pressure
最新试题
Which of the following items don’t belong to dock repair works?()
()connectors hold best if a wire is accidentally pulled or a connection becomes loose.
For a given exhaust gas boiler, what is the quantity of its evaporation mainly determined?()
Under MARPOL Code the ship to which it applies has to carry ()
A purge recovery system is used in a centrifugal air conditioning or refrigeration system to ()
The condensers located in various stages of a flash evaporator are cooled by()
Flame failure in an automatically fired auxiliary boiler can from a/an ()
If two A.C.generators are to be operated in parallel, the load is distributed evenly by()
When does auxiliary burner of incinerator put into operation? ()Ⅰ. start incinerator when it is coldⅡ. the sludge for dealing with is littleⅢ. the sludge for dealing with is largeⅣ. the water and impurity in sludge are too muchⅤ. the temperature in incinerator is lowⅥ. dealing with little solid rubbish
Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()