A.15;inlet value
B.15;inlet and outlet value
C.30;inlet value
D.30;inlet and outlet value
您可能感兴趣的试卷
你可能感兴趣的试题
A.filled with bilge water
B.filled with oil
C.filled with clean water
D.be emptied
A.the sensor of low oil level is fully covered by sludge
B.the coarse strainer before the pump in suction system is clogged
C.the screw pump is worn seriously and volumetric efficiency is decreased
D.bilge suction value is clogged
A.the filter is clogged
B.bilge suction value is clogged
C.suction value and discharge value of the pump do not open fully
D.screw pump is worn seriously and volumetric efficiency is decreased
A.separating oil too fast
B.the sensor flushed badly
C.the discharge solenoid value out of order
D.too low heating temperature
A.the monitoring equipment is out of order
B.separating effect becomes bad
C.inner wall is contaminated
D.separating effect becomes bad and inner wall is contaminated
When starting air-conditioner in the winter, we should open()in sequence.
Ⅰ.alve of warming
Ⅱ.alve of humidifier
Ⅲ.an
A.Ⅲ-Ⅱ-Ⅰ
B.Ⅲ-Ⅰ-Ⅱ
C.Ⅰ-Ⅲ-Ⅱ
D.Ⅱ-Ⅲ-Ⅰ
A.close Fan and Humidifier at the same time
B.firstly close Fan and then close humidifier immediately
C.firstly close humidifier and then close Fan immediately
D.firstly close humidifier and then close Fan after 30 seconds
A.decreased
B.increased
C.fixed
D.closed
A.decreased
B.increased
C.fixed
D.closed
A.the bearing near to the diesel engine
B.the intermediate bearing near to the thrust bearing
C.the intermediate bearing near to the sterntube
D.the bearing located at the middle of the diesel engine and the sterntube
最新试题
“Insufficiency of manning or insufficiency of certification of seafarers” is an identification of a()
The shipboard oil pollution emergency plan will be invalid after ()
Thermostatic steam pressure reducing valves are used in the fuel oil service system to control the()
By comparing the exhaust gas temperature of each cylinder, the operator can determine if the load is balanced throughout the engine. The device most commonly used is a()
During the diesel engine running, the water level of F.W expansion tank should normally kept in the () level of glass tube.
Diesel engine air start system check valves are opened by ()
Flame failure in an automatically fired auxiliary boiler can from a/an ()
If two A.C.generators are to be operated in parallel, the load is distributed evenly by()
The ISPS Code consists of a mandatory section-Part A, which shows()
()are used to digest the sewage to produce innocuous sludge in a biological sewage treatment plant.